Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Topic

Description

Diagnostics / Feed In Management / Utility Meter

Stability improved.

Extended reach-ability in networks

Additionally to http://solar-log and http://solar-log-xxxx (last 4 digits of SN)to access the Webinterface, http://solar-log.local and http://solar-log-xxxx.local are now added.
The new URLs are working on multiple OS like Windows, Linux, MacOS, iOS and Android, whereas the old URLs only work in combination with Windows.

FTP(s) export

Now the correct Solar-Log serial number is provided by the base_vars.js which is written from FTP(s) export.

Login passwords

We updated the storage format of all login passwords (User, Installer, Installer/PM) to an up to date cryptographic algorithm. Although the passwords are no longer part of the configuration and don’t change if you apply a configuration.

Mod485MOD 485

Communication stability improved (especially Feed In Management commands)

Mod485 MOD 485 RS485 payload communication

Serial communication configuration parameter “7 data bits” is now functional again.

Modbus Inverter Data Feedback Qac is wrong

If the Qac is > 32767 var or < -32768 var the value is wrong.

Modbus SCADA interface

Now the correct Solar-Log serial number is provided by the Modbus SCADA interface.

ModbusTCP PM interface

New registers where added which includes the current Pac of each generator device.

Self consumption

The energy for self consumption is now saved and displayed correct in all cases.