Whereas a few years ago there were only a handful of devices with which the system had to be compatible, today there are well over 300 2300 different devices with which the Solar-Log Base device family is compatible and the number is constantly growing.

...

Currently known problems for which we develop a solution:

Expand
titleBeta-Firmware 5.1.1
  • Fronius Gen24:
    Communication problems when selecting SunSpec Model Type "float".

  • Huawei (Hybridsystem):
    The WLAN dongle must not be installed, otherwise no communication with the Solar-Log Base is possible.

  • Kostal TCP:
    Currently, Piko CI may still experience communication outages on some days.

  • Sungrow:
    Communication problems with Sungrow inverters.

Expand
titleBeta-Firmware 6.0.0_160_20220610
  • ABB PRO device drivers
    Reactive power control over all Q modes (except cosPhi) with more than one device does not work correctly.

  • Huawei (Hybridsystem):
    The WLAN dongle must not be installed, otherwise no communication with the Solar-Log Base is possible.

  • Kostal TCP:
    Piko CI devices occasionally experience failures in device communication.

  • Varta device drivers
    Varta Flex Storage devices with a serial number starting with "601" are not recognized correctly.

none

Alpha Driver Description

Anchor
alphadescription
alphadescription

...

Alpha drivers are drivers coming directly from the development department. They have undergone internal software-based testing there, have completed the internal Solar-Log GmbH driver test tool and have been tested with a software simulator. The classification as an alpha driver is usually made when no direct test installations are available. The corresponding alpha driver can be requested by our customers for a beta test, via email. The tests are accompanied by our beta test team to ensure that all functions are guaranteed in the system. It may happen that we need a few days lead time to provide the appropriate resources in the development department.

...


Alpha drivers for which we are looking for specific test plants:
  • Fronius Gen24:
    Devices via RS485, connected to the Solar-Log Base + SunSpec Model Type "float" configured.

Info

If you are interested in an

...

Alpha driver,

...

fill out the

...

contact form

...

via this link

...

and submit this form on the subsequent confirmation of the ticket.

Beta Firmware
Anchor
betafirmware
betafirmware

Filename

Firmware

Solar-Log™ Model

Release Date

Release Notes (DE / EN)

Beta firmware

in combination with the Solar-Log MOD485.

This firmware is intended for use with the Solar-Log MOD485, it contains the previous beta firmware version 5.1.3-157.
Please only use this firmware version in connection with the Solar-Log MOD485 !

firmware_base_6.0.0_160_20220615

versions

firmware_base_beta_2024-04-12_45e689a2_6.1.0_Build_163.bin

6.

0

1.0

.

-

160

163

Base

15

12.

06

04.

2022

2024

Solar-Log

_ReleaseNotes_Beta_600_160_20220615_DE_EN.pdfBeta firmware versions

Release Notes 6.1.0 Build 163 - 12.04.2024 BETA

firmware_sl50_4.2.9-118_beta20221028.bin

4.2.9-118

SL50

28.10.2022

Solar-Log_ReleaseNotes_Beta_sl50_4.2.9-118_20221028_EN_DE.pdf

firmware_2000_4.2.9-118_beta20221028.bin

4.2.9-118

SL 4.Generation

28.10.2022

Solar-Log_ReleaseNotes_Beta_2000_4.2.9-118_20221028_EN_DE.pdf

firmware_base_5.1.3-157-beta220530.bin

5.1.3-157

Base

30.05.2022

Solar-Log_ReleaseNotes_Beta_513_157_20220530_EN_DE.pdf

firmware_sl50_4.2.9-118_beta20220530.bin

4.2.9-118

SL50

30.05.2022

Solar-Log_ReleaseNotes_Beta_sl50_4.2.9-118_20220530_EN_DE.pdf

firmware_2000_4.2.9-118_beta20220530.bin

4.2.9-118

SL 4.Generation

30.05.2022

Solar-Log_ReleaseNotes_Beta_2000_4.2.9-118_20220530_EN_DE.pdf

Special Firmware





firmware_base_5.1.3-157_20220608_refu.bin

5.1.3-157

Base

08.06.2022

firmware_base_5.1.3-157_20220608 Refu txt

firmware_base_5.1.1-155_20201221_refu.bin

5.1.1-155

Base

 

firmware

_base

_

5.1.1-155_20201221 Refu.docxfirmware_

sl50_4.2.7-116_20210218_refu.bin

4.2.7-116

SL50

 

firmware_sl50_4.2.7-116_20210218 Refu.docx


Devices with supported string visualization

Anchor
stringvisualization
stringvisualization

...

Alpha Driver
Anchor
alphadriver
alphadriver

Supported Components as Alpha Drivers

Inverter / components:

ABB

:

PVS-175

FIMER

:
Azzurro Hybrid Wechselrichter

PVS-175

Goodwe Hybrid

Growatt MIC/MOD/MID Series

Huawei Hybrid - compatibility extended for SUN2000-L Series models.
(In the implementation of the data channels, Solar-Log assumes the following technical configuration of the hybrid inverter: 2 strings have been assigned per MPPT).

Huawei Modbus 485 Hybrid:
SUN2000-2KTL-L0, SUN2000-2KTL-L1, SUN2000-3KTL-L1, SUN2000-4KTL-L1,
SUN2000-4.6KTL-L1, SUN2000-4.95KTL-L1, SUN2000-5KTL-L1, SUN2000-6KTL-L1,
SUN2000-3. 8KTL-USL0, SUN2000-5KTL-USL0, SUN2000-7.6KTL-USL0,
SUN2000-9KTL-USL0, SUN2000-10KTL-USL0, SUN2000-11.4KTL-USL0,
SUN2000-10KTL-M0, SUN2000-10KTL-M0, SUN2000-10KTL-M1,
SUN2000-12KTL-M1, SUN2000-4KTL-L0

Huawei Modbus 485 PV:
SUN8000-500KTL, SUN2000-8KTL-M2, SUN2000-175KTL-H0, SUN2000-185KTL-INH0, SUN2000-193KTL-H0,
SUN2000-168KTL-H1, SUN2000-185KTL-H1, SUN2000-196KTL-H1, SUN2000-200KTL-H2, SUN2000-196KTL-H3,
SUN2000-24.5KTL-M3, SUN2000-40KTL-NHM3, SUN2000-30KTL-A

Schneider Conext CL36

Sungrow CX Series:
SG36CX, SG60CX

Sungrow HX Series (Ethernet):
SG125HX, SG250HX

Sungrow RT Series:
SG3.0RT, SG4.0RT, SG5.0RT, SG6.0RT, SG7.0RT, SG8.0RT,SG10RT, SG12RT, SG15RT, SG17RT, SG20RT

Sungrow TCP - general revision of the driver, devices with Ethernet interface are compatible.

SMA Modbus:
Sunnyboy Storage (SBS3.7-10, SBS5.0-10, SBS6.0-10, SBS3.8-US-10, SBS5.0-US-10, SBS6.0-US-10)
Sunnyboy Storage 2.5 (SBS2.5-1VL-40)
Peak 3 (SHP 100-20, SHP 150-20, SHP 125-US-20, SHP 150-US-20, SHP 100-JP-20, SHP 150-JP-20)

Zucchetti Centro Sistemi S.p.a:

Intilion (Batterie):
scalestac, scalebloc

Mennekes AMTRON Professional, AMTRON Charge Control, AMEDIO Professional

Schneider Conext CL36

SolaX:

  • MEGA

SMA Modbus:

  • Peak 3 (SHP 100-20, SHP 150-20, SHP 125-US-20, SHP 150-US-20, SHP 100-JP-20, SHP 150-JP-20)

Sungrow Hybrid:
SH5.0RT-20, SH6.0RT-20, SH8.0RT-20, SH10RT-20, SH5.0RT-V112, SH6.0RT-V112, SH8.0RT-V112, SH10RT-V112, SH5.0RT-V122, SH6.0RT-V122, SH8.0RT-V122, SH10RT-V122


Security Hotfixes
Anchor
security_hotfix
security_hotfix