Release Notes 6.1.0 Build 163 - 12.04.2024 BETA
Firmware
Release Notes
Firmware releases extend the range of functions and contain improvements for the security, stability and reliability of your Solar-Log product. Compatibility of component drivers is improved by adaptations. The following release notes contain the most important new features.
Component Drivers - New
Topic | Description |
---|---|
GoodWe HT | GW73KLV-HT, GW100K-HT, GW110K-HT, GW120K-HT, GW136K-HTH, GW150K-HTH, GW225K-HT, GW225KN-HT, GW250K-HT, GW250KN-HT |
GoodWe Sunspec | New driver for GoodWe sunspec inverters: |
Intilion | New driver for scalebloc energy, power, powerboost and scalestac. |
Kehua SPI Series | SPI250K-B-H, SPI200K-B-H, SPI225K-B-H, SPI175K-B-H, SPI136K-BHV, SPI125K-B, SPI100K-B |
Kernel | ST0N 0825, ST0N 1225, ST0N 1625, ST0N 2425, ST0HS 0825, ST0HS 1225, ST0HS 1625, ST0HS 2425 |
SMA Tripower X | Sunny Tripower X 12, Sunny Tripower X 15, Sunny Tripower X 20, Sunny Tripower X 25 |
SolaXPower X3-Commercial | New driver for SolaXPower X3-Commercial inverter: X3-MGA-40K-G2, X3-MGA-50K-G2, X3-MGA-60K-G2, X3-MGA-20K-G2-LV, X3-MGA-25K-G2-LV, X3-MGA-30K-G2-LV, X3-MGA-35K-G2-LV, X3-FTH-80K, X3-FTH-100K, X3-FTH-110K, X3-FTH-120K, X3-FTH-125K, X3-FTH-136K-MV, X3-FTH-150K-MV, X3-FTH-40K-LV, X3-FTH-50K-LV, X3-FTH-60K-LV, X3-FTH-70K-LV |
Weidmüller | New charging station driver: AC SMART ADVANCED, AC SMART VALUE and AC SMART ECO |
Component Drivers - Adjustments & Extensions
Topic | Description |
---|---|
ABB Sunspec | New model: PVS-175-TL |
Azzurro V3 | New models:
Renamed models:
Removed model:
|
CCS | Support for usage as battery and consumption meter (bi-directional) added. |
Fronius RS422 / SolarAPI | New models from the ‘Symo Advanced’ series: 10.0-3-M, 12.5-3-M, 15.0-3-M, 17.5-3-M, 20.0-3-M |
Fronius SunSpec Modbus / SolarAPI | Power Management gets now refreshed at least every 30 seconds (or on change). |
Mennekes | Adding more Status and Error Codes. |
SMA Sunspec v2 | Speed up power management via Ethernet. |
Sofar Solar G3 | New models:
Renamed models:
Removed model:
|
SolarEdge | Speed up power management via Ethernet. |
Component Drivers - Bugfixes
Topic | Description |
---|---|
AC THOR | If the heating element on an AC THOR 9S had less then 9kW the target power we set was too low. |
Azzurro V3 | Power Management is now also working correctly if more than one inverter is connected to the same RS485 bus. |
ChargeX | Yield was too small by a factor of 10. |
ComLynx | Improved power management timing. |
Diehl AKO | Filter invalid values receiving from the inverter. |
Fox ESS H3 | The values yield, Pac and Idc are now stored correctly. |
Fox ESS R |
|
Fronius Gen24 | Now all bus addresses, not only 1, are found again during a device search when searching on RS485 (was an issue since 6.0.2). |
GoodWe Hybrid |
|
Growatt Gen X | MPP tracker 9 - 12 are now also monitored correctly. |
Growatt Modbus | Improved power management timing. |
Huawei Smart Logger | The yield is now monitored correctly. |
Huawei SUN2000 V2 | Driver stability improved. |
Huawei V1 | When steering to 0% Pdc values are very high for a short time. Now those values get filtered out. |
INVT | Improved power management timing. |
Kaco Ethernet | Daily yield is now computed correctly. |
Kaco RS485 | Improve calculation of active power limit. |
Kaco Sunspec | The data acquisition now works reliably after a Solar-Log reboot. |
Keba | Directly after a reboot triggered via Webinterface, no devices were found by device search, if the same search was performed before the reboot. |
Kostal Modbus TCP | The data acquisition now works reliably after a Solar-Log reboot. |
Kostal Standard |
|
Mencke&Tegtmeyer | Insolation value is now recorded correctly. |
Mennekes | Yield was too small by a factor of 10. |
MyPV | Status and Error messages are corrected. |
Omron | Status is now determined correctly. |
RCT Power | Calculation of yield adjusted. |
Schneider Electric iEM3000 | Support for active power control at the grid connection point. |
SMA Modbus | The data acquisition now works reliably after a Solar-Log reboot. |
SMA Speedwire | Directly after a reboot triggered via webinterface, no devices were found by device search, if the same search was performed before the reboot. |
SMA Sunpec v2 |
|
Sofar Solar G3 | Power Management is now also working correctly if more than one inverter is connected to the same RS485 bus. |
Solar-Log Pro | Yield was wrong if the Meter is connected to a MOD485. |
SolarEdge |
|
Solplanet | Improve power management. |
Sungrow |
|
Sungrow Hybrid | Yield data will now recording correctly. |
Varta |
|
Firmware adjustments, extensions & bug fixes
Topic | Description |
---|---|
Configuration / Data / Initial Yield |
|
Configuration / Devices / Configuration | Automatic distribution of MPP tracker power is now always equal to the total generator power of the device. |
Configuration / Direct Marketing | Following features are added:
|
Configuration / Direct Marketing | The settings now get saved instead of reset when a file upload is done before saving the changes. |
Configuration / Feed In Management / Reactive Power | It is now possible to configure U/Uref and P/Pn values with 3 instead of 2 decimal places for the Curves Q(P/Pn), CosPhi(P/Pn), Q(U/Uc), CosPhi(U/Uc). |
Device detection | Changed the default name for newly detected devices to “Device”. |
Device events | Fixed a bug where device events won’t be shown anymore and in the web portal the inverters were shown as offline. |
Extension modules | Communication stability increased if 1 of 2 extension modules has failed. |
Feed In Management Feedbacks without ModbusTCP PM license | Feedbacks which do not need ModbusTCP PM as feedback output now work also without a ModbusTCP PM license. |
Increase data acquisition stability in combination with meters | Increase data acquisition stability with specific meter configurations and not available meters. |
Missing Status/Error Strings | All Status/Error strings will be written again to base_vars.js during CSV Export via FTP. |
Mod485 extension module | Stability improved. |
Modbus TCP server | The Modbus TCP server now always accepts up to 4 parallel connections. |
Network Configuration | When the Solar-Log is assigned an address by a DHCP server, the Solar-Log's hostname is now displayed in the router in the format SOLAR-LOG-XXXX. The last four characters in the hostname correspond to the last four digits of the serial number. |
Network Configuration | Deny an incorrect subnetmask in the frontend and backend of the Solar-Log. Prevents saving of invalid configuration. |
Power Management | In rare cases 0% was sent as command instead of the correct value. |
Reactive Feed In Management - steering the cos(phi) with digital inputs | Steering the cos(phi) through 5 digital inputs of an Adam Box (configured via PM profiles) was not working as expected. In previous versions, only the first 4 digital inputs were working. |
Security and Stability | Several adjustments are done to increase the security and stability topics. |
System stability in case of corrupted data | Improve detection and cleanup of corrupted data which could lead to system instability. |