[Beta][External] 6.1.2 Build 165 - 16.07.2024

Firmware file

 

firmware_base_beta_6.1.2 Build 165_2024-07-16

Release Notes

 

Firmware releases extend the range of functions and contain improvements for the security, stability and reliability of your Solar-Log product. Compatibility of component drivers is improved by adaptations. The following release notes contain the most important new features.

Component Drivers - New

Topic

Description

Topic

Description

Ads-Tec StoraXe (Battery)

StorageRackSystem, PowerBooster

INVT XG

New driver for INVT XG series inverter: XG17KTR, XG20KTR, XG22KTR, XG25KTR, XG30KTR, XG33KTR, XG36KTR, XG40KTR, XG50KTR, XG50KTRL, XG60KTR, XG60KTRL, XG66KTRL, XG70KTRL, XG100KTR-F, XG110KTR-F, XG136KTR-LF, XG136KTR-XF, XG1KTL-S, XG1.5KTL-S, XG2KTL-S, XG2.5KTL-S, XG3KTL-S, XG3.68KTL-S, XG4KTL-S, XG4.2KTL-S, XG4.6KTL-S, XG5KTL-S, XG3KTL-2M, XG3.68KTL, XG4KTL, XG4.2KTL, XG4.6KTL, XG5KTL, XG6KTL, XG7KTL, XG8KTL, XG10KTL, XG7KTL1, XG8KTL1, XG10KTL1, XG3KTR-S, XG4KTR-S, XG5KTR-S, XG6KTR-S, XG8KTR-S, XG9KTR-S, XG10KTR-S, XG11KTR-S, XG12KTR-S, XG15KTR1-S

Component Drivers - Adjustments & Extensions

Topic

Description

Topic

Description

MyPV

The Solar-Log now always sends the correct target power to an AC Thor with less than 3kW of heating rods.

Delta

New models: M50A Flex, M100A Flex

Ginlong

The new version of Solis-3P15K-4G is now also supported.

GoodWe Hybrid

  • Following data channels will be stored additionally: Pac per phase, Iac per phase, Uac per phase, battery voltage, battery current

  • Newer ODM model names can now be read

Component Drivers - Bugfixes

Topic

Description

Topic

Description

Ginlong

Fix detection for some Solis80K-5G models.

GoodWe HT

Power management now works properly.

Kostal Standard

Speedup Ethernet communication .

ABB Sunspec

Negative production values are now ignored.

Diehl AKO

In some cases the devices were shown as offline even they provided valid data.

Fimer Sunspec

Negative production values are now ignored.

Fronius SunSpec

Fix communication and data collection during the night.

GoodWe Hybrid

Now also the data of a possibly second battery, which can be attached to the system, is monitored.

GoodWe Sunspec

SunSpec models are read correctly, even if communication is unstable.

Inepro

In some cases the yield was not recorded.

Platinum

In some cases the devices were shown as offline even they provided valid data.

SMA Sunspec

Increase communication stability.

Solar-Log Pro Meter

In some cases the yield was not recorded.

SolarEdge

Increase communication stability.

SolarEdge Hybrid

The device is now always detected as hybrid system and not as normal inverter without a battery unit.

Firmware adjustments, extensions & bug fixes

Topic

Description

Topic

Description

Device configuration

For devices with MPP trackers the module field of the first MPP Tracker was not configurable. This issue was introduced with firmware 6.1.0.

Legal Notices

Some Legal Notices for the used open source software were not shown in our local web-interface. This issue was introduced with firmware 6.1.0.

Link Local Addresses

The Link Local address will not be lost when switching between static IP and DHCP. This issue was introduced with firmware 6.1.0.

Networking

Gateway for Ethernet 2 can now be configured.

NTP

The time now also gets corrected if the time difference between Solar-Log and the NTP server is very high. This issue was introduced with firmware 6.1.0.

Decrease possibility of data corruption

An issue was found and fixed which leaded to data corruption in rare cases.

PM Feedbacks

PM Feedbacks can now be configured even if no devices are configured.

PM Feedbacks

Increase system stability in combination with invalid configurations.

RS485 Bus Analysis

The RS485 Bus Analysis was not functional since 6.1.0. After starting the analysis, the operation never finished.

System stability in case of corrupted data

Data which was detected as corrupt will now be recovered if possible, otherwise deleted as before this update.

Yield calculation

Some devices provide us a daily yield, which gets reset on 0 o’clock.
If the device does reset the daily at exactly 0 o’clock (different clock settings etc.) this leaded to a wrong daily yield. We improved the handing so this does not lead to a invalid yield for the whole day.