Release Notes 6.0.2 Build 162 - 25.09.2023 BETA

Release Notes

 

Firmware releases extend the range of functions and contain improvements for the security, stability and reliability of your Solar-Log product. Compatibility of component drivers is improved by adaptations. The following release notes contain the most important new features.

Component Drivers - New

Topic

Description

Topic

Description

Mennekes

Mennekes ev charger: ECU-BRx and ECU-BBx [ETH]

ChargeX

Aqueduct charging system: Aqueduct 1.0, Aqueduct 2.0 [ETH]

Fox ESS

Fox ESS R series inverter: R75,R100, R110, R120, R136 [RS485]

Fox ESS H3/AIO series hybrid inverter: AIO-H3-5.0, AIO-H3-6.0, AIO-H3-8.0, AIO-H3-10.0 [RS485]

Growatt

Inverter driver for Mod, Max and Mid series [RS485]

Component Drivers - Adjustments & Extensions

Topic

Description

Topic

Description

ChintPower Modbus

New models: 25(20)kW inverter series, 100kW(125kW)_1500V inverter series

Fronius Gen24

PM timeout is set to 30s this means if the Solar-Log stops sending PM commands the inverter will fallback to it’s PM fallback value.

Ginlong S5/S6

New models: S5-GR1P0.7K-1, S5-GR1P1K-M, S5-GR1P1.5K-M, S5-GR1P2K-M, Solis-3P5K-4G-AU-MX, Solis-3P8K-4G-AU-MX, Solis-1P6K-4G-US, Solis-1P7.6K-4G-US, Solis-1P8.6K-4G-US, S5-GR1P3.6K-M, S5-GR1P2.5K-M, S5-GR1P3K-M, S5-GR1P2.5K, S5-GR1P3K, S5-GR1P3.6K, S5-GR1P4K, S5-GR1P4.6K, S6-GR1P0.7K-M, S6-GR1P1K-M, S6-GR1P1.5K-M,S6-GR1P2K-M, S6-GR1P2.5K-M, S6-GR1P3K-M, S6-GR1P3.6K-M, S6-GR1P7K-M-LV, S6-GR1P2.5K, S5-GC25K, S5-GC30K, S5-GC33K, S5-GC36K-AU, S5-GC40K-AU, S5-GC40K-HV-AU, S5-GC50K-HV-AU, S5-GC50K IN, S5-GC60K IN, S5-GC60K-HV, S5-GC70K-HV, S5-GC25K-LV, S5-GC30K-LV, S5-GC36K-LV, S5-GC124K-HV, S5-GC124K-HV, Solis-80K-5G-PRO, Solis-110K-5G-PRO, Solis-100K-5G-PRO, GCI-230K-EHV-5G, Solis-250K-EHV-5G-PLUS, Solis-255K-EHV-5G-PLUS, Solis-185K-EHV-5G-US-PLUS, GCI-196K-EHV-5G-PLUS, GCI-215K-EHV-5G-PLUS, GCI-215K-EHV-5G-PLUS, S6-GR1P3K, S6-GR1P3.6K, S6-GR1P4K, S6-GR1P4.6K, S6-GR1P5K, S6-GR1P6K, S6-GR1P2.5K-LV, S6-GR1P3K-LV, S6-GR1P3.8K-LV, S5-GR1P7K2, S5-GR1P8K2, S5-GR1P7K, S5-GR1P8K, S5-GR1P9K, S5-GR1P10K, S5-GR1P6K, S5-GR1P7.6K, S5-GR1P8.6K, S5-GR1P8K, S5-GR1P9K, S5-GR1P10K, S5-GR3P3K, S5-GR3P4K, S5-GR3P5K, S5-GR3P6K, S5-GR3P8K, S5-GR3P9K, S5-GR3P10K, S5-GR3P12K, S5-GR3P13K, S5-GR3P15K, S5-GR3P17K, S5-GR3P20K, S5-GR3P23K, S5-GR3P25K, S5-GR3P12K, S5-GR3P13K, S5-GR3P15K, S5-GR3P5K, S5-GR3P6K, S5-GR3P8K, S5-GR3P9K, S5-GR3P10K, S5-GR3P5K-HV, S5-GR3P6K-HV, S5-GR3P8K-HV, S5-GR3P9K-HV, S5-GR3P10K-HV, S5-GR3P12K-HV, S5-GR3P15K-HV, S5-GR3P17K-HV, S5-GR3P20K-HV, S5-GR3P5K-LV, S5-GR3P6K-LV, S5-GR3P10K-LV

Adam I/O module

Communication status is now shown in local Web interface

KACO 485

New models: KACO blueplanet 50 NX3 M5, KACO blueplanet 60 NX3 M5

my-PV

New models: AC ELWA 2

Sungrow Hybrid

New models: SH3.0RS, SH4.0RS, SH5.0RS, SH5.0RT-20, SH6.0RT-20, SH8.0RT-20, SH10RT-20, SH5.0RT-V112, SH6.0RT-V112, SH8.0RT-V112, SH10RT-V112, SH5.0RT-V122, SH6.0RT-V122, SH8.0RT-V122, SH10RT-V122

Component Drivers - Bugfixes

Topic

Description

Topic

Description

ABB PVI/TRIO/Ultra/UNO

reactive power management fixed

Adam 4050

Functional improvements.

Azzurro V3

Driver is now named V3 instead of G3.

Etotal and PAC values during battery charging/discharging corrected.

CanadianSolar CSI-CT

Power management improved.

ChintPower Modbus

Power management improved.

Evoco

Reliability of yield data improved.

Fronius Hybrid

Imporved meter value monitoring when using Sunspec.

Ginlong 5G

For some models DC values are corrected/included in device table.

Huawei Smart Logger

The sign for the reactive power commands is now correct.

Huawei SUN2000 V2

Daily yield didn’t reset to 0 at midnight. If this update is installed the yield data wont increase for the rest of the day. If possible install it in the evening.

Huawei V2

Communication reliability improved.

Inepro

Yield is calculated correctly even if the meter has been installed the wrong way.

Kostal Sunspec

Include negative Pac values.

Kostal TCP

Communication stability improved.

Mod485 extension module

Improved interface recognition after solar-log reboot.

my-PV

After a firmware update from < 6.0, the AC ELWA was not fully functional anymore.

Oelmaier

Included in firmware generation 6

QCells

Reliability of yield data improved.

RCT Power

Reliability of yield data improved.

Schneider iEM3000

Reliability of yield data improved.

SMA Modbus

Communication improvement with enabled power management

SofarSolar G3

KTLX-G3 devices require to set power management registers in a batch.
Corrected PAC if the battery is charged/discharged

Solaredge Hybrid

If two batteries are installed battery values are now correct

Solarmax

Show correct status.

Solectria V4

Power management didn't work with newer inverter firmware versions.

Solplanet

Power and device detection management improved.

Sonnen Eco 8

Increase system stability during battery detection improved.

Reliability of yield data improved.

Sungrow

Fixed Communication over Modbus TCP

Sungrow Hybrid

Power management improved.

Varta

Communication reliability improved.

Reliability of yield data improved.

Firmware adjustments, extensions & bug fixes

Topic

Description

Topic

Description

Configurable feedback values for Adam box

On the tab Configuration / Feed In Management / Feedbacks it’s now possible to configure a minimum value which is higher than the maximum value.

Feedback value Modbus V3

Possible production power feedback register is filled without active direct marketing.

PM History wrong DM entries

PM history entry handling improved.

Wrong yearly and total yield displayed

Yield data calculation for Year and Total improved.

Solar-log loses Config after 3 years

System stability for a Solar-Log with a runtime over more than 3 years increased.

For FW5 from V5.1.2 (Build 157 - 06.07.2023) and for FW6 from V6.0.1 (Build 161 - 08.05.2023) and higher resolved.