Release Notes 6.0.2 Build 162 - 25.09.2023 BETA
Release Notes
Firmware releases extend the range of functions and contain improvements for the security, stability and reliability of your Solar-Log product. Compatibility of component drivers is improved by adaptations. The following release notes contain the most important new features.
Component Drivers - New
Topic | Description |
---|---|
Mennekes | Mennekes ev charger: ECU-BRx and ECU-BBx [ETH] |
ChargeX | Aqueduct charging system: Aqueduct 1.0, Aqueduct 2.0 [ETH] |
Fox ESS | Fox ESS R series inverter: R75,R100, R110, R120, R136 [RS485] Fox ESS H3/AIO series hybrid inverter: AIO-H3-5.0, AIO-H3-6.0, AIO-H3-8.0, AIO-H3-10.0 [RS485] |
Growatt | Inverter driver for Mod, Max and Mid series [RS485] |
Component Drivers - Adjustments & Extensions
Topic | Description |
---|---|
ChintPower Modbus | New models: 25(20)kW inverter series, 100kW(125kW)_1500V inverter series |
Fronius Gen24 | PM timeout is set to 30s this means if the Solar-Log stops sending PM commands the inverter will fallback to it’s PM fallback value. |
Ginlong S5/S6 | New models: S5-GR1P0.7K-1, S5-GR1P1K-M, S5-GR1P1.5K-M, S5-GR1P2K-M, Solis-3P5K-4G-AU-MX, Solis-3P8K-4G-AU-MX, Solis-1P6K-4G-US, Solis-1P7.6K-4G-US, Solis-1P8.6K-4G-US, S5-GR1P3.6K-M, S5-GR1P2.5K-M, S5-GR1P3K-M, S5-GR1P2.5K, S5-GR1P3K, S5-GR1P3.6K, S5-GR1P4K, S5-GR1P4.6K, S6-GR1P0.7K-M, S6-GR1P1K-M, S6-GR1P1.5K-M,S6-GR1P2K-M, S6-GR1P2.5K-M, S6-GR1P3K-M, S6-GR1P3.6K-M, S6-GR1P7K-M-LV, S6-GR1P2.5K, S5-GC25K, S5-GC30K, S5-GC33K, S5-GC36K-AU, S5-GC40K-AU, S5-GC40K-HV-AU, S5-GC50K-HV-AU, S5-GC50K IN, S5-GC60K IN, S5-GC60K-HV, S5-GC70K-HV, S5-GC25K-LV, S5-GC30K-LV, S5-GC36K-LV, S5-GC124K-HV, S5-GC124K-HV, Solis-80K-5G-PRO, Solis-110K-5G-PRO, Solis-100K-5G-PRO, GCI-230K-EHV-5G, Solis-250K-EHV-5G-PLUS, Solis-255K-EHV-5G-PLUS, Solis-185K-EHV-5G-US-PLUS, GCI-196K-EHV-5G-PLUS, GCI-215K-EHV-5G-PLUS, GCI-215K-EHV-5G-PLUS, S6-GR1P3K, S6-GR1P3.6K, S6-GR1P4K, S6-GR1P4.6K, S6-GR1P5K, S6-GR1P6K, S6-GR1P2.5K-LV, S6-GR1P3K-LV, S6-GR1P3.8K-LV, S5-GR1P7K2, S5-GR1P8K2, S5-GR1P7K, S5-GR1P8K, S5-GR1P9K, S5-GR1P10K, S5-GR1P6K, S5-GR1P7.6K, S5-GR1P8.6K, S5-GR1P8K, S5-GR1P9K, S5-GR1P10K, S5-GR3P3K, S5-GR3P4K, S5-GR3P5K, S5-GR3P6K, S5-GR3P8K, S5-GR3P9K, S5-GR3P10K, S5-GR3P12K, S5-GR3P13K, S5-GR3P15K, S5-GR3P17K, S5-GR3P20K, S5-GR3P23K, S5-GR3P25K, S5-GR3P12K, S5-GR3P13K, S5-GR3P15K, S5-GR3P5K, S5-GR3P6K, S5-GR3P8K, S5-GR3P9K, S5-GR3P10K, S5-GR3P5K-HV, S5-GR3P6K-HV, S5-GR3P8K-HV, S5-GR3P9K-HV, S5-GR3P10K-HV, S5-GR3P12K-HV, S5-GR3P15K-HV, S5-GR3P17K-HV, S5-GR3P20K-HV, S5-GR3P5K-LV, S5-GR3P6K-LV, S5-GR3P10K-LV |
Adam I/O module | Communication status is now shown in local Web interface |
KACO 485 | New models: KACO blueplanet 50 NX3 M5, KACO blueplanet 60 NX3 M5 |
my-PV | New models: AC ELWA 2 |
Sungrow Hybrid | New models: SH3.0RS, SH4.0RS, SH5.0RS, SH5.0RT-20, SH6.0RT-20, SH8.0RT-20, SH10RT-20, SH5.0RT-V112, SH6.0RT-V112, SH8.0RT-V112, SH10RT-V112, SH5.0RT-V122, SH6.0RT-V122, SH8.0RT-V122, SH10RT-V122 |
Component Drivers - Bugfixes
Topic | Description |
---|---|
ABB PVI/TRIO/Ultra/UNO | reactive power management fixed |
Adam 4050 | Functional improvements. |
Azzurro V3 | Driver is now named V3 instead of G3. Etotal and PAC values during battery charging/discharging corrected. |
CanadianSolar CSI-CT | Power management improved. |
ChintPower Modbus | Power management improved. |
Evoco | Reliability of yield data improved. |
Fronius Hybrid | Imporved meter value monitoring when using Sunspec. |
Ginlong 5G | For some models DC values are corrected/included in device table. |
Huawei Smart Logger | The sign for the reactive power commands is now correct. |
Huawei SUN2000 V2 | Daily yield didn’t reset to 0 at midnight. If this update is installed the yield data wont increase for the rest of the day. If possible install it in the evening. |
Huawei V2 | Communication reliability improved. |
Inepro | Yield is calculated correctly even if the meter has been installed the wrong way. |
Kostal Sunspec | Include negative Pac values. |
Kostal TCP | Communication stability improved. |
Mod485 extension module | Improved interface recognition after solar-log reboot. |
my-PV | After a firmware update from < 6.0, the AC ELWA was not fully functional anymore. |
Oelmaier | Included in firmware generation 6 |
QCells | Reliability of yield data improved. |
RCT Power | Reliability of yield data improved. |
Schneider iEM3000 | Reliability of yield data improved. |
SMA Modbus | Communication improvement with enabled power management |
SofarSolar G3 | KTLX-G3 devices require to set power management registers in a batch. |
Solaredge Hybrid | If two batteries are installed battery values are now correct |
Solarmax | Show correct status. |
Solectria V4 | Power management didn't work with newer inverter firmware versions. |
Solplanet | Power and device detection management improved. |
Sonnen Eco 8 | Increase system stability during battery detection improved. Reliability of yield data improved. |
Sungrow | Fixed Communication over Modbus TCP |
Sungrow Hybrid | Power management improved. |
Varta | Communication reliability improved. Reliability of yield data improved. |
Firmware adjustments, extensions & bug fixes
Topic | Description |
---|---|
Configurable feedback values for Adam box | On the tab Configuration / Feed In Management / Feedbacks it’s now possible to configure a minimum value which is higher than the maximum value. |
Feedback value Modbus V3 | Possible production power feedback register is filled without active direct marketing. |
PM History wrong DM entries | PM history entry handling improved. |
Wrong yearly and total yield displayed | Yield data calculation for Year and Total improved. |
Solar-log loses Config after 3 years | System stability for a Solar-Log with a runtime over more than 3 years increased. For FW5 from V5.1.2 (Build 157 - 06.07.2023) and for FW6 from V6.0.1 (Build 161 - 08.05.2023) and higher resolved. |